EasyManua.ls Logo

Bosch Solution 6000-IP CC615GWF - Page 28

Bosch Solution 6000-IP CC615GWF
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Solution 6000-IP
28
Bosch Security Systems 10/22 BLCC615R
Quick Start Guide
Areas > Area Properties >
Part Mode 1 Name
MENU 2-1-6
P a r t 1 A r e a 1 N a m e
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
Areas > Area Properties >
Part Mode 2 Name
MENU 2-1-7
P a r t 2 A r e a 1 N a m e
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
Areas > Area Properties >
Auto Arming
MENU 2-1-8
0 0
00 - Disabled
01 - 24 Hour TimeZone 09 - TimeZone 9 Name
02 - TimeZone 2 Name 10 - TimeZone 10 Name
03 - TimeZone 3 Name 11 - TimeZone 11 Name
04 - TimeZone 4 Name 12 - TimeZone 12 Name
05 - TimeZone 5 Name 13 - TimeZone 13 Name
06 - TimeZone 6 Name 14 - TimeZone 14 Name
07 - TimeZone 7 Name 15 - TimeZone 15 Name
08 - TimeZone 8 Name 16 - TimeZone 16 Name
Enter 0 - 16 + [OK] to assign the area to a TimeZone – Can
only be assigned to one TimeZone (0 = Disabled). To set
the start/stop and days of the week that the area will
automatically arm, refer to TimeZone menus.
Areas > Reporting >
Account Dest 1
MENU 2-2-0
0 0 0 0 0 0 0 0 0 0
Program the area account number for Destination 1 here
(Enter digits 0 – 9 + [OK] to save).
Areas > Reporting >
Account Dest 2
MENU 2-2-1
0 0 0 0 0 0 0 0 0 0
Program the area account number for Destination 1 here
(Enter digits 0 – 9 + [OK] to save).
Areas > Reporting >
Open Close Route
MENU 2-2-2
00 - Log Events Only 0 1
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
Use [] and [] keys or enter 0 - 4 + [OK] to program which
destination ‘Open and Close reports are sent to.
Areas > Timers >
Exit Time
MENU 2-8-0
0 6 0
Seconds
Enter 000 – 255 + [OK] to program the exit time in
seconds.
Areas > Timers >
Entry Time 1
MENU 2-8-1
0 2 0
Seconds
Enter 000 - 255 + [OK] to program the entry time in
seconds.
Areas > Timers >
Entry Time 2
MENU 2-8-2
0 4 0
Seconds
Enter 000 - 255 + [OK] to program the entry time in
seconds.
Areas > Timers >
Part Entry Time
MENU 2-8-3
0 6 0
Seconds
Enter 000 - 255 + [OK] to program the part entry time in
seconds.