EasyManua.ls Logo

Bosch Solution 6000-IP CC615GWF - Add RF Device I; Delete RF Device; Door Name I; Door Options

Bosch Solution 6000-IP CC615GWF
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Solution 6000-IP
36
Bosch Security Systems 10/22 BLCC615R
Quick Start Guide
Outputs > Properties >
Output Options
MENU 4-1-5
1 Off On Low Battery Y
2 Guest Control N
3 Reserved N
4 Monitor Overload Y
5 Monitor Device Fail Y
6 Alarm On Device Fail N
7 Block If All On N
8 Show Status On Keypad N
Outputs > Door Properties >
Door Name
MENU 4-2-0
D o o r 1 N a m e
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
Outputs > Door Properties >
Unlock TimeZone
MENU 4-2-2
0 0
00 - Disabled
01 - 24 Hour TimeZone 09 - TimeZone 9 Name
02 - TimeZone 2 Name 10 - TimeZone 10 Name
03 - TimeZone 3 Name 11 - TimeZone 11 Name
04 - TimeZone 4 Name 12 - TimeZone 12 Name
05 - TimeZone 5 Name 13 - TimeZone 13 Name
06 - TimeZone 6 Name 14 - TimeZone 14 Name
07 - TimeZone 7 Name 15 - TimeZone 15 Name
08 - TimeZone 8 Name 16 - TimeZone 16 Name
A single TimeZone can be assigned to each door. Use
the [] and [] keys to highlight door name, then press
[OK] to select. Enter 0 - 16 + [OK] to assign the door to a
TimeZone – can only be Assigned to one TimeZone (0 =
Disabled).
Outputs > Door Properties >
Door Options
MENU 4-2-3
1 Hold Off If Area Armed Y
2 Hold Off Auto Unlock N
3 Reserved N
4 Report Door Forced N
5 Alarm On Door Forced N
6 Report DOTL N
7 Alarm On DOTL N
8 Lift Door N
Outputs > RF Output >
Add RF Device
MENU 4-3-0
Delete RF Device
MENU 4-3-1
Test RF Device
MENU 4-3-2
Outputs > Macros >
Name
MENU 4-8-0
M a c r o s 1 N a m e
This menu allows you to program the name for each macro.
A maximum of 8 different macros can be configured. Macro
names can be up to 20 characters long.
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
Outputs > Macros >
Macro Rule
MENU 4-8-1
This menu allows you to program the script for each macro.
A maximum of 8 different macros can be configured. Macro
scripts can be up to 20 characters long.
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
Only the following characters are supported when
constructing macro scripts.
Script Character Character Represents
O Output
A Area All On
P Area Part 1 On
Q Area Part 2 On
M Macro
T TimeZone
H Holiday
Z Zone
D Door
F RF Keyfob Key
K Keypad Arrow Key
(Keypad keys incl. U/D/L/R)
Table 22: Macros Script Characters