Output Default Table
The table below list the default values for all Output parameters in the control panel. Outputs 1 to 4 are high current digital
outputs and Output 5 is the onboard relay output. Outputs 9 to 40 are only available if the optional modules are fitted.
Options marked N/A = Not Applicable.
Programming Option Output 1 Output 2 Output 3 Output 4 Output 5 Output 9 - 40
Output Name
External
Siren
Strobe
Light
Smoke Sensor
PWR
Internal
Siren
On Board
Relay
Output x Name
Event Type
36
(External
Siren)
48
(Strobe)
49
(Smoke Sensor
GND)
37
(Internal
Siren)
54
(Keyfob
Function 2)
00
(Not Used)
Event Assignment 0 0 0 0 0 0
Output Polarity
14
Speaker
Output
6
1 Shot Low +
Reset
11
Low 1 Shot
Open
6
1 Shot Low +
Reset
4
Open 1 Shot
Low
0
Open
To Low
Time Parameter
N° Of Hours 000 008 000 000 000 000
N° Of Minutes 005 000 000 005 000 000
N° Of Seconds 000 000 010 000 002 000
N° Of 1/10 Seconds 000 000 000 000 000 000
Output Options
Off On Low Battery Y Y N Y N N
Guest Control N N N N N N
Reserved N N N N N N
Monitor Overload Y Y Y Y N N
Monitor Device Fail Y Y N Y N N
Alarm On Device Fail N N N N N N
Block If All On N N N N N N
Show Status On Keypad N N N N N N
Table 18: Output Default Table
Output Programming
Outputs > Commands >
Output Status
MENU 4-0-0
Turn Output On/O
MENU 4-0-1
Output Array
MENU 4-0-2
Door Status
MENU 4-0-3
Door Array
MENU 4-0-4
Door Control
MENU 4-0-5
Macro Array
MENU 4-0-6
Outputs > Properties >
Output Name
MENU 4-1-0
O u t p u t 1 N a m e
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
Outputs > Properties >
Event Type
MENU 4-1-1
0 0 0
Use [] and [] keys or enter desired event type 0 – 255 +
[OK]. See output event type table for available options.