Solution 6000-IP
32
Bosch Security Systems 10/22 BLCC615R
Quick Start Guide
Inputs > RF Zone Properties >
Tamper Options
MENU 3-3-3-3
1 Enable Rear Tamper Y
2 Enable Case Tamper Y
3 Reserved N
4 Reserved N
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
Inputs > Global Input Options >
EOL Value
MENU 3-4-0
(*** System Wide Parameter ***) 0 5
00 - No EOL 08 - 6k8 Ohm
01 - 1k0 Ohm 09 - 8k1 Ohm
02 - 1k5 Ohm 10 - 10k Ohm
03 - 2k2 Ohm 11 - 6K8 Alarm + 2k2 Tamp
04 - 2k7 Ohm 12 - 10k Alarm + 10k Tamp
05 - 3k3 Ohm 13 - 22k Ohm
06 - 4k7 Ohm 14 - 3k3 Alarm + 6k8 Tamp
07 - 5k6 Ohm 15 - Split EOL 3k3 //6k8
Use [] and [] keys or enter 0 - 15, then press [OK] to
program globally the EOL resistor for all zones.
Inputs > Global Input Options >
Keyswitch Options
MENU 3-4-1
(*** System Wide Parameter ***) 0 0
00 - Latching All On/Off 05 - Pulse All On/Off
01 - Latching All On 06 - Pulse All On
02 - Latch Part On/O 07 - Pulse Part On/Off
03 - Latching Part On 08 - Pulse Part On
04 - Latching Off 09 - Pulse Part O
Use [] and [] keys or enter 0 - 9, then press [OK] to
program how the keyswitch will operate.
Inputs > Global Input Options >
Input Options
MENU 3-4-2
1 Tamper On Short N
2 Reserved N
3 Response Time 500msec N
4 Reserved N
5 Keyswitch Open Close Y
6 Alarm On Tamper N
7 Reserved N
8 Reserved N
(*** System Wide Parameter ***)
Inputs > PGM Input >
Keyswitch Options
MENU 3-5-0
0 0
00 - Disabled 03 - Simple RF On/Off
01 - Latching On/Off 04 - Bosch Serial Rcvr
02 - Pulse On/Off 05 - Crow Serial Rcvr (TBA)
Enter 0 - 8 + [OK] to select the interface method used for
the given RF receiver.
Inputs > Tamper Inputs >
Tamper Options
MENU 3-6-0
1 Display Panel Tpr Y
2 Report Panel Tpr Y
3 Audible Panel Tpr Y
4 Display Expander Tpr Y
5 Report Expander Tpr Y
6 Audible Expander Tpr Y
7 Reserved N
8 Reserved N
Inputs > Input Testing >
Walk Test All Zones
MENU 3-9-0
Inputs > Input Testing >
Walk Test A Zones
MENU 3-9-1
Inputs > Input Testing >
Sensor Watch Time
MENU 3-9-2
(*** System Wide Parameter ***) 0 3 0
Days
Enter 0 – 255 + [OK] to program the sensor watch time in
days (0 = Disabled).