39
Bosch Security Systems 10/22 BLCC615R
Solution 6000-IP
Quick Start Guide
Comms > IP Reporting >
Receiver IP
MENU 5-6-0
Dest Nº 1
1
Digits
12
0 0 0 0 0 0 0 0 0 0 0 0
Dest Nº 2
1
Digits
12
0 0 0 0 0 0 0 0 0 0 0 0
Use [] and [] keys to scroll cursor, enter 0 – 9 for IP
address digits and press [OK] to save when finished.
Comms > IP Reporting >
Receiver Port
MENU 5-6-1
Dest Nº 1 0 7 7 0 0
Dest Nº 2 0 7 7 0 0
Enter base station port number - must be 5 digits within
the range 0 to 65535. Use [] and [] keys to scroll
cursor. Press [OK] to save.
Comms > IP Reporting >
Poll Rate
MENU 5-6-2
0 3 6 0
Seconds x10
Enter 0000 - 9999 + [OK] to program the poll rate time in
seconds (x10) for both Destination 1 and/or Destination 2.
Comms > IP Reporting >
ACK Wait Time
MENU 5-6-3
0 1 0
Seconds
Enter 0 - 255 + [OK] to program the acknowledge wait
time in seconds for both Destination 1 and/or Destination
2.
Comms > IP Reporting >
IP Format
MENU 5-6-4
00 - Conettix 0 1
01 - Conettix NNC (Anti Replay)
02 - CSV IP ALARM
03 - SIA UDP
04 - SIA
03 - Reserved
06 - CSV IP UDP
07 - Reserved
08 - Reserved
Enter 0 - 7 + [OK] to program the IP format for both
Destination 1 and/or Destination 2.
Comms > IP Reporting >
Retry Count
MENU 5-6-5
0 3
Enter 0 – 15 + [OK] to program the IP retry count (0 = No
Retry) for both Destination 1 and/or Destination 2.
Comms > IP Reporting >
Encryption Key
MENU 5-6-6
Dest Nº 1
1 Digits 32
0 0 0 0 0 0 0 0 0 0 0
Dest Nº 2
1 Digits 32
0 0 0 0 0 0 0 0 0 0 0
The encryption key must match the encryption key on the
base station receiver for communication to take place. To
remove encryption set MENU-5-6-6 to all zeros.
Comms > IP Reporting >
Conettix NNC
MENU 5-6-7
Dest Nº 1 0 0 0 0 0 0 0 0
Dest Nº 2 0 0 0 0 0 0 0 0
The NNC number is used to prevent anti-replay attacks
when reporting in Connetix format. The NNC number will
be assigned by the control room at the time the account
is setup. Like the account number the NNC will always be
unique.
Comms > IP Reporting >
SIA IP Prefix
MENU 5-6-8
Account
Dest Nº 1
1
Digits
16
0 0 0 0 0 0 0 0 0 0
Account
Dest Nº 2
1
Digits
16
0 0 0 0 0 0 0 0 0 0
Account Prefix
Dest Nº 1
1
Digits
6
0 0 0 0 0 0
Account Prefix
Dest Nº 2
1
Digits
6
0 0 0 0 0 0
Receiver Prefix
Dest Nº 1
1
Digits
6
0 0 0 0 0 0
Receiver Prefix
Dest Nº 2
1
Digits
6
0 0 0 0 0 0
Highlight the parameter that you want to program, then
press [OK] to select. Use the [] and [] keys to scroll
cursor left and right. Use the [0] – [9] keys or the [] and
[] keys to scroll characters, then press [OK] to save. Press
[OFF] to clear text from the current cursor position.

Table of Contents

Related product manuals