41
Bosch Security Systems 10/22 BLCC615R
Solution 6000-IP
Quick Start Guide
Comms > Comms Test >
Test Report Period
MENU 5-9-2
(*** System Wide Parameter ***) 0 1
00 - No Test Report 08 - Reserved
01 - Every Day 09 - Reserved
02 - Every Week 10 - Reserved
03 - Every Month 11 - Reserved
04 - Every 2 Days 12 - Reserved
05 - Every 3 Days 13 - Reserved
06 - Every 4 Days 14 - Every Hour
07 - Every 5 Days 15 - Every 12 Hours
MENU 5-9-2 programs the interval between automatic
test reports. Use [] and [] keys or enter [0] to [15] + [OK]
to program.
Comms > Comms Test >
Test Report Options
MENU 5-9-3
1 Test If No Other Rpt N
2 Test On Siren Reset Y
3 Reserved N
4 Reserved N
5 Reserved N
6 Reserved N
7 Reserved N
8 Reserved N
Comms > Reporting
Test Route
MENU 5-9-4
00 - Log Events Only 0 1
01 - Dest 1 + Log
02 - Dest 2 + Log
03 - Dest 1 & 2 + Log
04 - Dest 2 If 1 Fails
Use [] and [] keys or enter 0 - 4 + [OK]. Enter single
option only. (*** System Wide Parameter ***).
Device Programming
Devices > Commands >
Device Status
MENU 6-0-0
LAN Secure
MENU 6-0-1
LAN Scan
MENU 6-0-2
LAN Watch
MENU 6-0-3
Keypad Volume
MENU 6-0-7
Keypad Contrast
MENU 6-0-8
Keypad Backlight
MENU 6-0-9
Devices > Keypads & Readers >
Name
MENU 6-1-0
K e y p a d 1 N a m e
Use the [] and [] keys to scroll cursor left and right.
Use the [0] – [9] keys or the [] and [] keys to scroll
characters, then press [OK] to save. Press [OFF] to clear
text from the current cursor position.
Devices > Keypads & Readers >
Area Options
MENU 6-1-2
1 All On Arming Allowed Y
2 Part On Arming Allowed Y
3 Disarming Allowed Y
4 Single Button Control Y
5 All User Areas N
6 Zero Exit Time N
7 PIN To Change Area N
8 Home Area Only N