4.4.3 Electrical Input Power Ratings
Plug the Power Supply into a single-phase, grounded, 3-wire, 50 or 60 Hz power source.
Table 4.4
lists the current and fuse ratings for the various models.
The ground screw on the rear of the actuator must be connected to earth ground with #8
gauge wire.
* To be hardwired by customer.
Table 4.4 Input Power requirements
Model Power Current Rating NEMA Connector
For 15 kHz
models
3300 W 200V -
240V
21 Amp Max. @ 200V / 25 Amp
fuse
*
For 20 kHz
models
1250 W 200V -
240V
7 Amp Max. @ 200V / 20 Amp
fuse
NEMA L6-20P Plug
1250 W 100V -
120V
14 Amp Max. @ 100V / 20 Amp
fuse
NEMA 5-15P Plug
2500 W 200V -
240V
14 Amp Max. @ 200V / 20 Amp
fuse
NEMA L6-20P Plug
4000 W 220V -
240V
25 Amp Max. @ 220V / 25 Amp
fuse
*
For 30 kHz
models
750 W 100V -
120V
10 Amp Max. @ 100V / 20 Amp
fuse
NEMA 5-20P Plug
750 W 200V -
240V
5 Amp Max. @ 200V / 20 Amp
fuse
NEMA L6-20P Plug
1500 W 200V -
240V
10 Amp Max. @ 200V / 20 Amp
fuse
NEMA L6-20P Plug
For 40 kHz
models
400 W 200V -
240V
3 Amp Max. @ 200V / 20 Amp
fuse
NEMA L6-20P Plug
400 W 100V -
120V
5 Amp Max. @ 100V / 20 Amp
fuse
NEMA 5-15P Plug
800 W 200V -
240V
5 Amp Max. @ 200V / 20 Amp
fuse
NEMA L6-20P Plug
800 W 100V -
120V
10 Amp Max. @ 100V / 20 Amp
fuse
NEMA 5-15P Plug