82 1019572 REV. 03
5.1 Technical Specifications
5.1.1 Requirement Specifications
The 2000X Actuator requires compressed air. The factory air source must be “clean (5
micron) and dry”, that is, does not include moisture or lubricants. The Actuator requires
70 psi minimum pressure for operation and cooling, and can require up to 100 psig
maximum, depending on the application. The following table lists environmental
specifications for the ultrasonic welder.
All electrical input power connections are to the Power Supply.
5.1.2 Performance Specifications
The following tables detail some of the performance specifications associated with the
2000X Actuator.
Minimum Stroke: 1/8” / 3.2 mm
Maximum Stroke: 3-3/4” / 95.2 mm (for a 4" cylinder)
Table 5.1 Environmental Specifications
Environmental Concern Acceptable Range
Humidity 30% to 95% non-condensing
Ambient Temperature +5°C to +50°C (+41°F to +122°F)
Storage/Shipping Temperature
-25°C/-13°F to +55°C/+131°F
(+70°C/+158°F for 24 hours)
Table 5.2 Max. welding force, dynamic trigger force, dynamic follow-through
Cylinder
Size
Max. clamp force
at 100 psig/690
kPa and 4"stroke
Dynamic triggering
range
Dynamic follow-
through range
Stroke length
1.5" 130 lbs / 578 N 5-159 lbf / 22-707 N 5-159 lbf / 22-707 N 4" / 101.6 mm
2.0" 270 lbs / 1.2 kN
5-282 lbf / 22-
1.25 kN
5-282 lbf / 22-
1.25 kN
4" / 101.6 mm
2.5" 440 lbs / 1.96 kN
10-440 lbf / 44-
1.96 kN
10-440 lbf / 44-
1.96 kN
4" / 101.6 mm
3.0" 640 lbs / 2.84 kN
10-636 lbf / 44-
2.83 kN
10-500 lbf / 44-
2.22 kN
4" / 101.6 mm
3.25" 770 lbs / 3.42 kN
10-725 lbf / 44-
3.22 kN
10-500 lbf / 44-
2.22 kN
4" / 101.6 mm
Table 5.3 Maximum Traverse Speed (Application dependant)
Down and Return
Speed
Up to 7 inch/ 177.8 mm per sec. max at 3.5-inch / 88.9 mm
stroke, 90 psi (all cylinder sizes)