1019572 REV. 03 55
6. Use jack screws to fine adjust the system level. A 3/16" allen wrench should be used for the
3/8"-16 x 3/4" jack screws.
7. Verify earth ground is connected with #8 gauge wire to the ground terminal on the rear of the
actuator.
4.5.3 Actuator (Alone)
The actuator (alone) is intended for installation on your custom-made mounting support.
It is located in place with a mounting pin and secured using three metric bolts.
1. Lift the actuator from the box. Carefully lay the assembly on its right side (NOT on the side with
the linear encoder).
2. Use of a guide pin is suggested. It is not provided with the actuator. If you require a guide pin,
use a solid metal dowel pin, 12mm diameter, which must not extend into the actuator more than
0.40 inch (10mm) from your support.
CAUTION
In a custom installation, the actuator must be mounted on an I-beam
or other rigid structure. The mounting surface must be flat within
0.004 in (0.1mm) Total Indicator Reading, in a tolerance zone of 16 x
3.5 in (410 x 90 mm).
CAUTION
The actuator support bolts for the 2000X-Series actuators are metric,
M10 x 1.5 thread pitch, 25mm long. The support pin and mounting
bolts must not extend more than 0.40 in (10 mm) into the actuator,
otherwise, binding or damage to the carriage may occur.
CAUTION
DO NOT use 900-Series M10 x 1.25 mounting bolts. They have a
different thread pitch and will not interchange with those used on the
2000X-Series.