5
Power status Indicates whether an AC or DC power supply is installed in the specified power
supply slot and the status of the power supply, which can be one of the
following:
Installed (Shutdown) – The power supply has shut down. A power supply
will shut down due to flapping, or if a shut down is enabled manually using
the power-off power-supply command. Refer to Enabling a power supply
shutdown” on page 199.
Installed (OK) – The power supply is functioning properly and supplying
power to the device and installed modules.
Failed – The power supply is not functioning and is not supplying power to
the device and installed modules.
not present – There is no power supply installed in the slot.
Installed (Failed or Disconnected) - The power supply is not functioning, or
the power supply is not connected to the device and installed modules.
Total power budget for device The sum of all power (in watts), used by all power supplies currently functioning
in the device. Refer to “Maximum power consumption for Brocade MLXe router
components” on page 218.
Total power used by system core The total power used by the management modules, switch fabric modules, and
fans. Each component consumes different amounts of power.
Total power used by LPs The total power used by the interface modules. Each module type consumes
different amounts of power.
Total power available The total power budget for the device minus the total power used by the system
core and the installed interface modules.
Slot Power-On Priority The configured power-on priority of each interface module.
Slot num
Slot1 – Slot16
4-slot device: Slot1 – Slot4
8-slot device: Slot1 – Slot8
16-slot device: Slot1 – Slot16
32-slot device: Slot1 – Slot32
The
slot num is the device slot number.
The priority of each device slot as configured by the
lp-slot-priority command.
The priority can be 1 (low, default) – 8 (high). If the amount of power supplied to
the device falls below a minimum threshold, the device slots with the lowest
priority will likely lose power. For information about using the
lp-slot-priority
command, refer to “Changing priority of slots for interface modules” on
page 178.
Fans
Fan number Information about fans in the device.
Status The fan status of a fan can be OK or Failed:
OK – The fan is functioning properly and is keeping the temperature of
each module within an acceptable range.
Failed – The fan is not working or the fan control module cannot control
the fan.
Speed Fan speed can be one of four settings:
Low – The fan is functioning at 50 percent of capacity.
Medium – The fan is functioning at 75 percent of capacity.
Medium-high – The fan is functioning at 90 percent of capacity.
High – The fan is functioning at 100 percent of capacity.
Temperature readings
Active and Standby Mgmt
Module
The temperature of the active and standby management modules.
Fan number The temperature of fan0 and fan1.
TABLE 30 show chassis command output (Continued)
Field Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems MLXe Series and is the answer not in the manual?

Brocade Communications Systems MLXe Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelMLXe Series
CategoryControl Unit
LanguageEnglish

Related product manuals