EasyManuals Logo

Brocade Communications Systems MLXe Series User Manual

Brocade Communications Systems MLXe Series
274 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #169 background imageLoading...
Page #169 background image
Brocade MLXe Series Hardware Installation Guide 157
53-1003030-01
Managing the device
5
Power-on priority of the device slots
Status of the fans
Temperature readings of the management, switch fabric, interface, and fan control modules
and the interval at which the system reads the temperature of these modules
MAC address of the device
To display this information, enter the show chassis command at any level of the CLI.
Brocade# show chassis
*** Brocade MLX-4 chassis ***
---POWERS ---
Power 1 (32011000 - AC 1200W): Installed (OK)
Power 2: not present
Power 3: not present
Total power budget for device = 1200 W
Total power used by system core = 183 W
Total power used by LPs = 386 W
Total power available = 631 W
Slot Power-On Priority and Power Usage:
Slot1 pri=1 module type=NI-MLX-1Gx20-GC 20-port 10/100/1000 Copper Module power
usage=156W
Slot4 pri=1 module type=NI-X-OC48x8 8-port OC48/12 STM16/STM4 Module power
usage=230W
--- FANS ---
right fan tray (fan 1): Status = OK, Speed = MED-HI (90%)
right fan tray (fan 2): Status = OK, Speed = MED-HI (90%)
--- TEMPERATURE READINGS ---
Active Mgmt Module: 36.500C 49.625C
Standby Mgmt Module: 36.250C 51.0C
SNM1: 37.0C
SNM2: 38.0C
SNM3: not present
LP1 Sensor1: 41.5C
LP1 Sensor2: 50.625C
LP4 Sensor1: 39.0C
LP4 Sensor2: 49.250C
LP4 Sensor3: UNUSED
LP4 Sensor4: 38.5C
LP4 Sensor5: 47.750C
LP4 Sensor6: UNUSED
Fans are in auto mode. Temperature Monitoring Poll Period is 60 seconds
Table 30 describes the show chassis command output.
TABLE 30 show chassis command output
Field Description
Powers
Power num, part num The Power num is the power supply number as positioned in the device. The
number of power supplies are as follows:
4-slot devices: 1 – 3
8-slot devices: 1 – 4
16-slot devices: 1 – 8
32-slot devices: 1 – 8
The
part num is the part number of the power supply purchased. This applies
to AC and DC power supplies.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brocade Communications Systems MLXe Series and is the answer not in the manual?

Brocade Communications Systems MLXe Series Specifications

General IconGeneral
BrandBrocade Communications Systems
ModelMLXe Series
CategoryControl Unit
LanguageEnglish

Related product manuals