184 Brocade MLXe Series Hardware Installation Guide
53-1003030-01
Using alarms to collect and monitor device status
5
Jan 3 15:03:54 | Major | LP 1 | Optic 1 - Alarm
Jan 3 15:02:21 | Major | LP 1 | Optic 2 - Not Present
Jan 3 15:02:21 | Major | LP 1 | Optic 5 - Not Present
Jan 3 15:02:21 | Major | LP 1 | Optic 7 - Not Present
Jan 3 15:02:21 | Major | LP 1 | Optic 8 - Not Present
Jan 3 15:02:21 | Major | LP 1 | Optic 10 - Not Present
Jan 3 15:02:21 | Major | LP 1 | Optic 11 - Not Present
Jan 3 15:02:21 | Major | LP 1 | Optic 12 - Not Present
Jan 3 15:02:21 | Major | LP 1 | Optic 13 - Not Present
Jan 3 15:02:21 | Major | LP 1 | Optic 14 - Not Present
Jan 3 15:02:22 | Major | LP 1 | Optic 16 - Not Present
Jan 3 15:02:22 | Major | LP 1 | Optic 17 - Not Present
Jan 3 15:02:22 | Major | LP 1 | Optic 18 - Not Present
Table 39 describes how to use the show alarm command to display alarm information.
TABLE 39 Displaying alarm log information
Description Syntax
To display the default alarm levels. show alarm default
To display all current alarms of a specific severity:
critical, major, or minor.
Alarms displayed depend on what you have configured
the alarm logs to record.
show alarm severity [ critical | major |
minor ]
Use to display all alarms in the alarm logs. Use the
history operand to display the alarm history log.
show alarm [history] all
To display all alarms in the alarm log for all devices in
the chassis.
Alarms displayed depend on what you have configured
the alarm logs to record.
show alarm [history] chassis all
To display all alarms in the alarm log related to
all subsystems within the chassis or events for
a particular subsystem
(where subsystem is power supply or fan)
(where x is the device number)
show alarm [history] chassis subsystem
all |
x
To display all alarms in the alarm log for all
management modules and subsystems for the
management modules.
show alarm [history] mp all
To display all alarms in the alarm log related to
a specific management module
(where
n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and all alarms for it’s subsystems.
show alarm [history] mp n all
To display all alarms in the alarm log related to
temperature information for a management
module
(where
n, module number is 1-3 for MLX/XMR
and 1 for CER/CES)
and a specific fan
(where x, is the temperature device number).
show alarm [history] mp n temperature
[all |
x]
To display all alarms in the alarm log for all interface
modules and subsystems for the management
module.
show alarm [history] lp all