IV-26
2.2.15 Chute ASSY exit
1) Disconnect the connector of the motor ASSY DUP on the chute ASSY out and
release the cable from the clips.
2) Remove 2 screws securing the chute ASSY exit to the chute ASSY out.
3) Pull out the chute ASSY exit from the left side surface of the chute ASSY out.
Note:
When replacing the chute ASSY exit, be careful to avoid the actuator full on the chute
ASSY out.
Fig.4-41
Left
Chute ASSY exit
Actuator full
Screw, M3x10