EasyManua.ls Logo

Brother HL-4570CDW - Sensitivity Adjustment of Density Sensor (Maintenance Mode: Code 72); Performing the Developing Bias Voltage Correction (Maintenance Mode: Code 83); Performing the Adjustment of Inter-Color Position Alignment (Maintenance Mode: Code 66); If You Replace the High-Voltage Power Supply Pcb Assy4-7

Brother HL-4570CDW
432 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-7
Confidential
4. IF YOU REPLACE THE LASER UNIT
What to do when replacing the laser unit
- Sensitivity adjustment of density sensor (Maintenance mode: code 72)
- Performing the developing bias voltage correction (Maintenance mode: code 83)
- Performing the adjustment of inter-color position alignment (Maintenance mode: code 66)
4.1 Sensitivity Adjustment of Density Sensor
(Maintenance Mode: Code 72)
Make sensitivity adjustments of the density sensor in accordance with “1.4.18 Sensitivity
adjustment of density sensor” in Chapter 5.
4.2 Performing the Developing Bias Voltage Correction
(Maintenance Mode: Code 83)
Perform developing bias voltage correction in accordance with “1.4.25 Developing bias
voltage correction” in Chapter 5.
4.3 Performing the Adjustment of Inter-color Position
Alignment (Maintenance Mode: Code 66)
Perform adjustment of inter-color position alignment in accordance with “1.4.12 Adjustment of
inter-color position alignment” in Chapter 5.