72
Calix ODC-80 Installation Guide
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© 2001-2003 Calix. All Rights Reserved.
Maintain external cable connections
Check external cable connections at least once a year. External cable is defined as any cable
or wire that enters the cabinet from an external source.
Visually inspect all cables for signs of physical damage. If damage is present cables
should be repaired or replaced, if possible, per local site practices.
Check all outside plant copper connections for complete and secure connection.
Ensure that all cable management accessories provide a clean appearance. Replace
any fastening devices (i.e. tie wraps) so that they include all cables being secured.
Check all fiber optic connectors to ensure that they are securely fastened.
Check all connections on the cabinet ground bar for a tight and secure fit.
Check all protector modules and fiber modules to ensure that all devices are
securely seated.
Check all conduits to ensure that any material used to seal between the cable and
the conduit is still present and providing a complete seal.