The hot-water heater with the boiler can be operated with various energy
sources.
Turn rotary push button (Fig. 110,6) until the menu symbol operating
mode (Fig. 111,3) flashes.
Press rotary push button.
Turn rotary push button until the desired operating mode is displayed:
Gas operation
Electrical operation, output level 1 (900 W)
Electrical operation, output level 2 (1800 W)
Gas operation and electrical operation output level 1 (900 W)
Gas operation and electrical operation output level 2 (1800 W)
Press the rotary push button to save the set operating mode. To revert
to the original setting: Press back button (Fig. 110,7).
230 V electrical operation is only possible when the vehicle is connected
to the 230 V power supply.
With output level 1 (900 W), the current consumption is 3.9 A. With out-
put level 2 (1800 W), the current consumption is 7.8 A.
Turn rotary push button (Fig. 110,6) until the fan menu symbol
(Fig. 111,4) flashes.
Press rotary push button.
Turn rotary push button until the required value is displayed:
OFF: Fan is switched off.
VENT: Air circulation
ECO: Low fan setting
HIGH: High fan setting
BOOST: Fast room heating. Boost is available if the current room
temperature is at least 10 °C below the selected room temperature.
Press rotary push button to save the value set. If you do not wish to
change the value originally set: Press back button (Fig. 110,7).
Turn rotary push button (Fig. 110,6) until the timer menu symbol
(Fig. 111,9) flashes.
Press rotary push button. The start time is displayed and the hour dis-
play flashes.
Turn rotary push button until the hour of the selected start time is dis-
played.
Press rotary push button. The minute display flashes.
Turn rotary push button until the minute of the selected start time is dis-
played.
Press rotary push button.
Proceed in the same way to set the switch-off time, the required room
temperature, the hot water setting and the fan setting.
Press rotary push button. The timer is activated. The timer symbol
(Fig. 111,9) flashes when the timer is programmed and active.
Operatin
modes
Selecting operating mode:
Setting the fan: