7.4
Troubleshooting
7.4 FRESH BREW GROUP ERRORS
FRESH BREW GROUP ERROR - X
ERROR
11:25 |19 February 2017
131°
Error page
7.5 STEAM ERRORS
STEAM ERROR - 1
ERROR
11:25 |19 February 2017
131°
Error page
Error
NO.
POSSIBLE CAUSE INTERVENTION
1 Mechanical fault during the start procedure.
Open the upper front door.
Check the Fresh Brew group.
If necessary, replace.
2 0 position not detected by the sensor.
Open the upper front door.
Check the Fresh Brew group.
If necessary, replace.
3
The opening waiting time of the
Fresh Brew group has elapsed.
Open the upper front door.
Check the Fresh Brew group.
If necessary, replace.
4
The waiting time of half opening of the
Fresh Brew unit has elapsed.
Open the upper front door.
Check the Fresh Brew group.
If necessary, replace.
5 7KHZDLWLQJWLPHRIWKH¿OWHUFORVLQJKDVHODSVHG
Open the upper front door.
Check the Fresh Brew group.
If necessary, replace.
6 7KHZDLWLQJWLPHRIWKH¿OWHURSHQLQJKDVHODSVHG
Open the upper front door.
Check the Fresh Brew group.
If necessary, replace.
7 7KHZDLWLQJWLPHRIWKH¿OWHUFOHDQLQJKDVHODSVHG
Open the upper front door.
Check the Fresh Brew group.
If necessary, replace.
8 The water waiting time has elapsed.
Open the upper front door.
Check the Fresh Brew group.
If necessary, replace.
POSSIBLE CAUSE INTERVENTION
Heating waiting time elapsed.
Switch the machine off.
Access the inner parts.
Check the heating element.
If necessary, replace.