7-79
Alarm
NO.
Steps
ALARM / CAUSE
CORRECTIVE ACTION
P189 CHECK EVAPORATOR FAN MOTOR
This device is checked twice in Pretrip - once in Test 2 and again in Test 8.
TRIGGER-ON TEST 2: Normal amps for the 1EVCON contactor coil are 0.05 to 2.0 Amps (12 VDC).
The circuit tests outside this range.
TRIGGER-ON TEST 9: Normal amps for the Evaporator Fan motor are 0.7 to 3.5 Amps (460 VAC).
The circuit tests outside this range.
UNIT CONTROL: Engine and standby operation: Pretrip will fail and display "PRE-TRIP FAIL AND
COMPLETED".
RESET CONDITION: Auto Reset if Pretrip is started again, or alarm may be manually reset via key-
pad or by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (See Note 1 Page 7-1) Operate the unit through the appropriate modes to see if any active alarm oc-
curs. Continue with the steps below as necessary.
1
Determine Which Test Triggered This Alarm
a. Review active alarm list.
Make a note of all alarms.
b. Clear active alarm list.
c. Restart and monitor Pretrip.
Stop Pretrip during Test #3 by holding = Key for
6 seconds.
d. Review active alarm list for Alarm
189.
If alarm is present, follow steps 2thru 4 If alarm is not
present, follow Steps 5 thru 8
12 VDC
CIRCUIT
2
Check 1EVCON
a. Inspect Evaporator Fan Motor coil
and wire connections.
No damage to coil.
No damaged or corroded pins.
b. Check contactor coil resistance.
Refer to Section 2.12.
3
Check 1EVCON Amp Draw
a. Check 1EVCON amp draw.
Use Component Test Mode (Section 5.1.2) to test.
Refer to Section 2.12 for amp values. View current
draw in Data List.
4
Check 1EVCON Wiring
a. Inspect harness & control box
connector pins & terminals. (See
wiring schematic Section 10.)
See Note 2 & Note 5 on Page 7.2.
No physical damage to harness.
No damaged or corroded pins.
Additional steps on the next page.