3.15 FUNCTIONAL PARAMETERS
COO L DEFROST ALARM START-STOP
ERUTAREPMETXOBTNIOPTES
ALARM LIST
SELECT
MANUAL
DEFROST
SUOUNITNOCTAEH
START--STOP/
CONTINU OUS
1. Press the SELECT key until the MessageCenter displays “PRESS ↑↓
TO VIEW SETTINGS”.
2. When the UP ARROW key is pressed, the Function List will scroll down. When the
DOWN ARROW key is pressed, the Function List will scroll up. Refer to Table 3--2 for a
list of parameters and available settings.
3. To change one of the Functions, bring the Function you wish to change into the MessageCenter, and press
= key. TO SCROLL, THEN = TO SAVE will display in the MessageCenter. Pressing either UP or
DOWN ARROW key will display the parameter selections available for that Function. The MessageCent-
er will flash, indicating that a change to the displayed parameter selection has not been entered into
memory.
4. Continue pressing UP or DOWN ARROW key until the desired parameter selection is displayed, then
press the = key. The MessageCenter will stop flashing. The new parameter selection is now in memory. If
the = key is not pressed within 10 seconds, the MessageCenter will display FUNCTION NOT
CHANGED. This will display for 5 seconds, then return to the last Functional Parameter displayed. If no
further keys are pressed, the default display will return in another 10 seconds.
PRESS TO VIEW SETTINGS
NOTE
The microprocessor may be configured with all of
the functions locked or individual functions may
have been locked. Any Function that is displayed
with a padlock symbol cannot be changed from the
keypad.
+34. 5° F
--20.0