EasyManua.ls Logo

Carrier VECTOR 1550 Series - SPECIFIC R-452 A REFRIGERANT WARNING AND CAUTION

Carrier VECTOR 1550 Series
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62-61753-21
1-6
1.4 SPECIFIC R-452A REFRIGERANT WARNING
AND CAUTION
R-452A is an A1 non-flammable refrigerant
blend; however certain of its constituents
are considered A2L midly flammable.
For this raison, it is imperative that the sys-
tem of a vector unit utilizing R-452A refrig-
erant be reclaim to a sufficient vaccum to
ensure all residual refrigerant is removed
from the system
Follow the R-452A refrigerant reclaim / re-
covery procedure before performing any
“Hot work” including but not limited to
brazing or welding on a unit that has been
charged with R-452A, to prevent flare up of
residual A2L refrigerant constituents
Refrigerant must be reclaimed until equip-
ment gauge indicates 20 inHG (-0.6bar) of
vacuum.
Refer to Section 8.5.2Removing The R-
452A Refrigerant Charge
Refer to the Service Bulletin SB06-16 for
additional information
CAUTION
As distinct of R404A refrigerant, R-452A
has slidding properties more important and
not negligeable between vapour state and
liquid state.
For a given temperature, the liquid state
pressure value and the vapour state pres-
sure value, of the R-452A refrigerant are
differents.
Refer to section 10 for Temperature pres-
sure chart

Table of Contents