62-61753-21
3-13
3.9 MANUAL DEFROST
COOL DEFROST ALARM START-STOP
ERUTAREPMETXOBTNIOPTES
ALARM LIST
SELECT
MANUAL
DEFROST
SUOUNITNOCTAEH
DEFROST CYCLE STARTED
START--STOP/
CONTINUOUS
DEFROST LIGHT
1. Press the MANUAL DEFROST key. The DEFROST light will come on and the
MessageCenter will display DEFROST CYCLE STARTED for 5 seconds, or
flash CANNOT START DEFROST CYCLE for 5 seconds.
dF
--20.0
When DEFROST mode CANNOT be manually initiat-
ed "CANNOT START DEFROST CYCLE" is displayed
in the MessageCenter. This will occur when:
DTT is above 4°C (40°F) OR
The engine has not run 15 seconds after starting
OR
The unit is in Pretrip OR
There is an active shutdown Alarm.
TIP
The Manual Defrost Key can be used at any
time to start a Defrost Cycle as long as the
preceding conditions are met.
NOTE
Refer to Section 4.5.6 for more detailed infor-
mation on DEFROST.