2.8.4 Remote Temperature Sensors
The unit is provisioned to connect a up to three remote
temperature sensors directly to the microprocessor.
The microprocessor may be configured to display the
sensor reading in the Unit Data display and to record
the sensor reading in the Data Recorder. A user speci-
fied name may be configured for both sensors, this
name will be displayed (recorded) rather than the de-
fault Remote Sensor #1, Remote Sensor #2 or Re-
mote Sensor #3 name.
2.8.5 IntelliSet/ProductShield
The LogiCOLD Microprocessor offers over 48 parame-
ters that may be set depending on the product being
carried. IntelliSet allows the owner to pre-program
product specific settings into the microprocessor and
give the settings a name. The operator may then call
up these settings by simply selecting the IntelliSet
name.
In addition to the ability to pre-set the microprocessor
parameters, the IntelliSet option includes Prod-
uctShield. ProductShield is a group of nine Configura-
tions which may be set to provide enhanced product or
unit protection under extreme ambient conditions.
2.8.6 Remote Control Panel
The unit may be fitted with an optional remote control
panel. The panel displays refrigerated compartment
set point, compartment temperature and operating
mode (heat, cool or defrost). The set point may be set
and the unit may be started and stopped using the
remote panel.
This compact panels can be mounted to suit the indi-
vidual operator’s preferences - in the cab, on the front
bulkhead, or in the refrigerated compartment (including
in the wall itself). See Section 3.19.2 for more infor-
mation on the remote control panels.
2.9 ENGINE DATA
1.498 liters
(91.41 in
3
n)
16.7 KW (22.4 hp) @1900 rpm
NOTE: Refer to Table 2-1 for engine speed settings
7.8 liters (8.24 U.S. quarts) - 50/50 mix mono propylene glycol - never to exceed 60/40
Starts to open 81 to 83°C (177 to 182°F) Fully open at 95°C (203°F)
140 to 150
Bars (1991 to 2133 psig)
Winter: Diesel No. 1 Summer: Diesel No. 2
4 amps per plug at 12 VDC
Intake and Exhaust -Cold = 0.18 to 0.22 mm (0.0071 to 0.0087 inch)
Engine compression must be above 27.2 Bars (400 psig)
2.8 To 4.2 Bars (40 to 62 psig) - Engine in high speed
Oil Pressure Safety
Switch (ENOPS)
Closes, on pressure rise, at 1.22 Bar (18 psig)
Opens, on pressure fall, at 0.82 Bar (12 psig)
Refer to Section 8.1 for information on service intervals.