Carrier VECTOR 1550 Series - Figure 4-2. Range Lock Settings - Non Overlapping; Figure 4-3. Range Lock Settings - Overlapping

Carrier VECTOR 1550 Series
270 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
62-61753-21
4-8
Range Lock1& 2
Range2is set for
--17.8° to --30°C
(0° to --22°F)
Range1is set for
--2.2° to +12.8°C
(28° to 55°F)
--30 --23.3 --17.8 --12.2 --6.7 4.4 10.0 15.6 7.621.121.1--
°C
--22 --10
0
10 20 40 50 60 0703
80
°F
Range 2
Range 1
Figure 4-2. Range Lock Settings - Non Overlapping
--30 --23.3 --17.8 --12.2 --6.7 4.4 10.0 15.6 7.621.121.1--
°C
--22 --10
0
10 20 40 50 60 0703
80
°F
Range1always has priority
when Range 1 & 2 overlap
Range1is set for 0° to 5.6°C
(32° to 42°F)
Set for Continuous
Range2is set for --30° to 32°C
(--22° to 89.6°F)
Set for Start--Stop
Range
1
Range 2
Figure 4-3. Range Lock Settings - Overlapping