62-61753-21
1-7
CAUTION
Do not vapor charge R-404A or R-452A. On-
ly liquid charging is acceptable.
CAUTION
The scroll compressor achieves low suc-
tion pressure very quickly. Do not use the
compressor to evacuate the system below
0 psig. Never operate the compressor with
the suction or discharge service valves
closed (frontseated). Internal damage will
result from operating the compressor in a
deep vacuum.
Do not direct water or steam into the gen-
erator openings. Do not allow any soap and
water solutions to enter the generator.
Under no circumstances should anyone at-
tempt to repair the Logic or Display
Boards. Should a problem develop with
these components, contact your nearest
Carrier Transicold dealer for replacement.