62-61753-21   
Input fuse blows when charger is 
turned on 
Short in 12 volt wiring causing 
overload of charger 
Input fuse blows repeatedly, even 
when not connected 
Charger does not taper back after 
charging for a few minutes 
Test battery for 
defect according 
to battery manu-
facturer’s instruc-
tions 
Open input fuse 
 
Charger is not receiving AC input 
Replace. 
 
Using a voltme-
ter, confirm 
charger is receiv-
ing correct (nom-
inal) 380V AC. If 
not check input 
connections. 
Charger output is not connected to 12 volt battery 
Check output 
wiring connec-
tions to battery. 
Low output voltage measured 
across charger output 
Battery not connected to charger. It is 
normal to measure 12 volts or less across 
charger output with no battery connected 
Check charging 
leads from 
charger to battery 
Reverse polarity connection to 
battery has caused charger to 
stop charging 
Internal DC fuse blown and possible 
damage to current carrying components