7-"TELEMATICS"APPLICATION
“FuelTheftDelta”
NOTE:The“FuelTheftDelta”windowisonlyrequiredfor
growerswhointendtousethefueltheftalarmfeatureof
theAFSConnecttelematicspackage.
Usethe“FuelTheftDelta”windowtosetthethresholdfor
whenafueltheftalarmistriggered.
WhenthesystemispoweredON,the“T elematics”appli-
cationcomparesthecurrentfuelleveltothefuellevelthat
wasrecordedbeforethesystemwaspoweredOFF .The
fueltheftalarmistriggeredwhenthedifference(ordelta)
betweenthesetwomeasurementsexceedsthepercent-
ageinthe“FuelTheftDelta”window.
NOTE:ThefueltheftalarmappearsontheAFSConnect
webportal.
Theacceptablerangeofvaluesforthe“FuelTheftDelta”
windowis1-20%Thedefaultsettingis5%.
Pressthe“FuelTheftDelta”windowtoaccessthepop-up
keypad.
RAIL14DSP1635BA19
Usethekeypadtoenteravaluefrom1-20%.
Pressthe“Enter”buttononthekeypadtosavethevalue.
RAIL14DSP1633BA20
7-7