8-DIAGNOSTICS
“PrecisionFarming”faulttable
Fault
number
FaulttitleAdvisorymessageAction
PF-100
GPSreceiver
communication
lost
Positiondatanotavailableuntil
communicationrestored.Checkdisplay
“connectiontype.”Recyclepower.If
problemcontinues,contactdealer.
Thesystemhaslostcommunication
withtheGPSreceiver.Ensurethat
theproperconnectiontypehasbeen
selectedforthevehicletype(Home>
Toolbox>GPS).Checkconnections.
Cyclepowertothesystem.
PF-101
GPSreceiver
positionlost
GPSReceiverUnabletoDetermine
Position.EnsureGPSantennaisnot
obstructed.
TheGPSreceiverisunabletoprovide
atwo-dimensionalcoordinateposition.
Checkthatatleast3satellitesarein
viewandthatthereceiverdoesnothave
anobstructedviewofthehorizon.
PF-102Workingwithout
taskselected
Anactivegrower,farm,eld,andtask
mustbeselectedbeforedatacanbe
logged.(Home>Performance>Prole)
Thesystemmusthaveagrower,farm,
eld,andtaskdenedinordertolog
data.Createorselectanactivegrower,
farm,eld,andtask.
PF-103Memorydevicenot
detected
Dataloggingdisabled.Insertmemory
deviceandrecyclepowertoenabledata
logging.
Ifthe“WritetoCard”windowissetto
“Yes”ortheGPSLocationwindowis
settoanythingbut“NotInstalled,”the
systemchecksforthepresenceofa
memorydeviceatpowerON.Inserta
memorydeviceandcyclepowertothe
system.
PF-104Memorydevice
removed
Dataloggingdisabled.Insertmemory
deviceandrecyclepowertoenabledata
logging.
Thesystemdetectedthepresenceofa
memorydeviceandthendetectedthat
thedevicewasremoved.Datalogging
willstop.Thememorydevicemustbe
reinsertedandpowertothesystem
mustbecycledtoenablelogging.
PF-105Memorydevice
90%full
Archivedataonmemorydeviceand
removeunwantedlesviaHome>Data
Management>Deletescreen.
Thememorystickhas90%ofitsusable
memoryused.Datawillneedtobe
removedfromthememorysticksoon.
PF-106
Memorydevicefull
Dataloggingdisabled.Archivedataon
datacardandremoveunwantedles
viaHome>DataManagement>Delete
screen.
Thereisnomorememoryspace
remainingonthememorystick.Data
willnolongerbesavedtothedevice.
PF-107
Taskleisfull.
Thecurrentactivetaskhasreachedthe
maximumlesize.
Anewtaskisautomaticallycreatedto
ensurethatdatacontinuestobelogged.
PF-108Mapmemory
exceeded
WarningNewdatawillberecordedbut
notshownondisplaymap.
Thecurrenton-screenmapdatasize
hasbeenexceeded.Datawillcontinue
tologtotheremovablememorystick
butwillnotbedisplayed.Aneweld
mustbeselectedorcreatedtoviewnew
mapdata.
PF-109Areacalibrationnot
valid
Theareacalibrationisoutofthe
acceptablerange.
Performanewareacalibrationforthe
currentgrower,farm,andeld(Home>
Calibration>Area).
8-9