6-MAINTENANCE
Oilreservoirbreather
WARNING
Burnhazard!
Beforeperforminganyserviceonthehydraulicsystem,youmustallowittocool.Hydraulicuid
temperatureshouldnotexceed40°C(104°F).
Failuretocomplycouldresultindeathorseriousinjury.
W0241A
WARNING
Pressurizedsystem!
Neverattempttodrainuidsorremovelterswhentheengineisrunning.Turnofftheengineand
relieveallpressurefrompressurizedsystemsbeforeservicingthemachine.
Failuretocomplycouldresultindeathorseriousinjury.
W0905A
Replacetheoilreservoirbreatherlterevery1000h.
1.Releaseallthepressureinthehydraulictank.Referto
page6-12.
2.Cleanthetopofthehydraulicoiltank,andcleanthe
coveroftheoilreservoirbreatherlter.
3.Loosenthelocknut(1)andremovethecover(2).
4.Pulloutthelterelement(3).
5.Installanewlterelement.
6.Installthecover(2)andlockwiththelocknut(1).
Tightenthelocknut(1)to1.92.8N·m(1.42.1lb
ft).
SMIL16MEX1396BA1
6-56