9-ACCESSORIES
Auxiliaryhydrauliccircuits
Breakerauxiliaryhydrauliccircuits(1-way)
Themachinecanbeprovidedwithabreakerauxiliaryhydrauliccircuit.Thistypeofcircuitissetasasingleacting
circuit(1-way).Thesingleactinghydrauliccircuitisdedicatedonlyfortheattachmentsuchashydraulicbreaker.
Hydraulicconnections
Thetwostopvalvesarelocatedoneachsideofthearmtoallowproperandsafeconnectionoftheattachment
hydrauliclinestothebreakerauxiliaryhydrauliccircuit.
SMIL18MEX0065BA1
Open(A1)/Close(A2)toolofthestopvalve
19mmwrench
Hydraulicconnection(B)QuickdisconnectJISB8363G-9,10(G1/2male)andcap
Deliverypressure
Left-handhose
DischargepressureRight-handhose
Operationalsettings
Theowrate/pressurecharacteristicofthebreakerauxiliaryhydrauliccircuitissettingbymeanstheenginepower
applied.
Thebreakerauxiliaryspecicationsforbreakeraresetfromfactory:
maximumowrate(P1,P2)60.0L/min(15.9USgpm)withenginesetat2100RPM
maximumoperatingpressure
220bar(3190psi)