15-27.
TROUBLE
SHOOTING--GYROS.
(Cont).
TROUBLE
PROBABLE
CAUSE
REMEDY
HORIZON
BAR
OSCILLATES
Central
filter
dirty.
Check
filter.
Clean
or
replace
OR
VIBRATES
EXCESSIVELY.
filter.
Suction
relief
valve
im-
Adjust
or
replace
relief
valve.
properly
adjusted.
Faulty
suction
gage.
Substitute known-good
suction
gage
and
check
gyro
indication.
Replace
suction
gage.
Defective
mechanism.
Substitute
known-good
gyro
and
check
indication.
Replace
in-
strument.
Excessive
vibration.
Check
panel
shock-mounts.
Re-
place
defective
shock-mounts.
EXCESSIVE
DRIFT
IN
Central
air
filter
dirty.
Check
filter.
Clean
or
replace
EITHER DIRECTION.
filter.
Low
vacuum.
relief
valve
Adjust
or
replace
relief
valve.
improperly
adjusted.
Faulty suction
gage.
Substitute
known-good
suction
gage
and
check
gyro
indication.
Replace
suction
gage.
Vacuum
pump
failure.
Check
pump.
Replace
pump.
Vacuum
line
kinked
or
Check
lines
for
damage
and
leaking.
leaks. Repair
or
replace
dam-
aged
lines, tighten
connections.
DIAL
SPINS
IN
ONE
Operating
limits
have
been
Replace
instrument.
DIRECTION
CONTINU-
exceeded.
OUSLY.
Defective
mechanism.
Substitute known-good
gyro
and
check
indication.
Replace
instrument.
SHOP
NOTES:
Change
2
15-13

Table of Contents

Other manuals for Cessna 177 SERIES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cessna 177 SERIES and is the answer not in the manual?

Cessna 177 SERIES Specifications

General IconGeneral
ManufacturerCessna
Engine TypePiston
Wingspan35 ft 6 in (10.82 m)
Seating Capacity4
Number Built4, 295
EngineLycoming O-360
Horsepower180 hp
Maximum Takeoff Weight2, 500 lb (1, 134 kg)

Related product manuals