Control Installation Chore-Tronics® 3 Control
102
MT2398C
Maximum Feed Runtime Alarm Input
If the Maximum Feed Runtime Alarm is used, the Input for the alarm must be connected to one of the Digital (DI) Inputs of the IO board. A dry contact
relay must be connected to the IO board. The coil of the relay should energize whenever the fill system’s hopper level switch closes (See Figure 30).
DI5
12V
DI6
230 VOLT, 50/60 HZ,
OR CONTROL PANEL
FROM DISCONNECT
1 PHASE SUPPLY
FILL SYSTEM
CONTROL UNIT
L2 OR N
L1
HOPPER LEVEL
CONTROL
1 HP MAX
230V, 1 PHASE
FILL MOTOR
(DI) of your Choice
Item Description
1 I/O Board Digital Input (DI)
terminal of your Choice
Figure 30. Max Feed Runtime Alarm Input Wiring
1
Dry Contact Relay