Chore-TronicsĀ® 3 Control Control Installation
MT2398C
103
Airspeed Sensor Wiring
The Airspeed Sensor requires a three conductor wire to connect the Sensor to one of the Digital (DI)
Inputs on the IO board. It is recommended that the digital input chosen is adjacent to one of the 12 volt
outputs on the IO board (Figure 31). The Brown wire on the Sensor needs to be connected to the +12 volt
output, the Green wire on the Sensor needs to be connected to the ground terminal of the digital input
being used, and the White wire needs to be connected to the DI(x) terminal of the digital input being used.
2
(DI) of your Choice
Item Description
1 Airspeed Sensor
2 I/O Board Digital Input (DI)
terminal of your Choice
Figure 31. Airspeed Sensor Wiring
1
GREEN
BROWN
WHITE
Feed Scale Wiring
If one or more Feed Scales are used, they need to be connected to one of the Digital (DI) Inputs on the IO
board using Twisted Pair Wire. Connect the switch located on the side of the Feed Scale to the IO Board
using the blue and brown wires (Figure 32). See manual MT1811 for more information.
Item Description
1 Feed Scale
2 I/O Board Digital Input (DI)
terminal of your Choice
Figure 32. Feed Scale Wiring
2
(DI) of your Choice
1