Operation
CHANNELS : It sets the high voltage channel for output. Select Function Key
[DEFAULT] means to use the “DEF. CHANNELS” settings in “TEST
CONTROL.” Select Function Key [SETUP] means to reset the high
voltage channel for output.
SCANNER : It sets the output mode of A190201/A190202 SCANNER. It can select
[ PS ], [ PC ], [ SC ], [ P+SC ] and [ PS+C ]. It is only valid
when the LINK SETUP in the SYSTEM of 19020/19020-4 is set to
SCANNER.
Please follow the model to set the output channel, for instance, the 19020
can set the output channel to CH1~CH10 while the 19020-4 can only set
the channel to CH1~CH4. The message line on the test screen will show
“Module Fail” if set otherwise and the test is unable to start.
DC Withstand Voltage Test Mode (DC) (for Model 19020/19020-4/19022/19022-4)
VOLTAGE : It sets the voltage required for DC withstand voltage test.
HIGH LIMIT : It sets the high limit of leakage current.
LOW LIMIT : It sets the low limit of leakage current. The range is smaller than the high
limit of leakage current or OFF.
ARC LIMIT : It sets the ARC limit, 0 means OFF.
TEST TIME : It sets the time test required, 0 means continue test.
RAMP TIME : It sets the time required for ramping to the set voltage, 0 means OFF.
DWELL TIME : It sets the time required for DWELL, 0 means OFF.
(It does not judge the high and low limit of leakage current during DWELL
TIME but only when the set range is within the high limit.)
FALL TIME : It sets the time required for falling to low voltage from set, 0 means OFF.
CHANNELS : It sets the high voltage channel for output. Select Function Key
[DEFAULT] means to use the “DEF. CHANNELS” settings in “TEST
CONTROL.” Select Function Key [SETUP] means to reset the high
voltage channel for output.
SCANNER : It sets the output mode of A190201/A190202 SCANNER. It can select
[ PS ], [ PC ], [ SC ], [ P+SC ] and [ PS+C ]. It is only valid
when the LINK SETUP in the SYSTEM of 19020/19020-4 is set to
SCANNER.
Please follow the model to set the output channel, for instance, the 19020
can set the output channel to CH1~CH10 while the 19020-4 can only set
the channel to CH1~CH4. The message line on the test screen will show