Remote Operation
5-41
CONFigure:PARAllel:INITial
Type: All Channel
Description: Set Load into/exit parallel mode.
Setting Syntax: CONFigure:PARAllel:INITial<space><CRD | NR1>
Setting Parameters: <CRD | NR1>, OFF(0), ON(1)
Setting Example: CONF:PARA:INIT ON Set Load to into parallel mode.
CONF:PARA:INIT 0 Set Load to exit parallel mode.
Query Syntax: CONFigure:PARAllel:INITial?
Return Parameters:<CRD>, OFF, ON [Unit = None]
Query Example: CONF:PARA:INIT?
CONFigure:PARAllel:MODE
Type: Channel-Specific
Description: Set the parallel mode.
Setting Syntax: CONFigure:PARAllel:MODE<space><CRD | NR1>
Setting Parameters: <CRD | NR1>, NONE(0), MASTER(1), SLAVE(2)
Setting Example: CONF:PARA:MODE MASTER Set parallel mode to MASTER.
CONF:PARA:MODE 0 Set parallel mode to NONE.
Query Syntax: CONFigure:PARAllel:MODE?
Return Parameters:<CRD>, NONE, MASTER, SLAVE [Unit = None]
Query Example: CONF:PARA:MODE?
CONFigure:SOUNd
Type: Channel-Specific
Description: Set the buzzer on/off in Load.
Setting Syntax: CONFigure:SOUNd<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, OFF(0), ON(1)
Setting Example: CONF:SOUN OFF Set buzzer to OFF.
CONF:SOUN 1 Set buzzer to ON.
Query Syntax: CONFigure:SOUNd?
Return Parameters:<CRD>, OFF, ON [Unit = None]
Query Example: CONF:SOUN?
CONFigure: SYNChronous:MODE
Type: Channel-Specific
Description: Set the synchronization mode.
Setting Syntax: CONFigure: SYNChronous:MODE<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, NONE(0), MASTER(1), SLAVE(2)
Setting Example: CONF:SYNC:MODE MASTER Set sync. mode to MASTER.
CONF:SYNC:MODE 0 Set sync. mode to NONE.
Query Syntax: CONFigure: SYNChronous:MODE?
Return Parameters:<CRD>, NONE, MASTER, SLAVE [Unit = None]
Query Example: CONF:SYNC:MODE?
CONFigure:VOLTage:LATCh
Type: Channel-Specific
Description: Set the action type of Von.
Setting Syntax: CONFigure:VOLTage:LATCh<space><CRD | NR1>
Setting Parameters:<CRD | NR1>, OFF(0),ON(1)
Setting Example: CONF:VOLT:LATC OFF Set Von latch function to OFF.
CONF:VOLT:LATC 1 Set Von latch function to ON.
Query Syntax: CONFigure:VOLTage:LATCh?
Return Parameters:<CRD>, OFF, ON [Unit = None]

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63600 Series and is the answer not in the manual?

Chroma 63600 Series Specifications

General IconGeneral
Series63600
Operating Temperature0°C to 40°C
ModesCC, CV
InterfaceGPIB, USB
ProtectionOCP, OTP, OVP
Voltage Resolution1mV
CoolingForced Air

Related product manuals