Programmable DC Electronic Load 63600 Series Operation & Programming Manual
disable.
CONF:SHOR:KEY 1 Set SHORT key function to
enable.
Query Syntax: CONFigure:SHORt:KEY?
Return Parameters: <CRD>, DISABLE, ENABLE [Unit = None]
Query Example: CONF:SHOR:KEY?
CONFigure:DIO:IN1
Type: Frame-Specific
Description: Set the DI1 type the pin No.10 in System I/O Port.
Setting Syntax: CONFigure:DIO:IN1<space><NR1>
Setting Parameters: <NR1>, 0 ~ 2
0:NONE
1:EXTERNAL LOAD ON/OFF
2:REMOTE INHIBIT
Setting Example: CONF:DIO:IN1 2 Set DI1 to REMOTE INHIBIT.
CONF:DIO:IN1 0 Set DI1 to NONE.
Query Syntax: CONFigure:DIO:IN1?
Return Parameters: <NR1>, 0 ~ 2 [Unit = None]
Query Example: CONF:DIO:IN1?
CONFigure:DIO:IN2
Type: Frame-Specific
Description: Set the DI2 type the pin No.44 in System I/O Port.
Setting Syntax: CONFigure:DIO:IN2<space><NR1>
Setting Parameters: <NR1>, 0 ~ 2
0:NONE
1:EXTERNAL LOAD ON/OFF
2:REMOTE INHIBIT
Setting Example: CONF:DIO:IN2 2 Set DI2 to REMOTE INHIBIT.
CONF:DIO:IN2 0 Set DI2 to NONE.
Query Syntax: CONFigure:DIO:IN2?
Return Parameters: <NR1>, 0 ~ 2 [Unit = None]
Query Example: CONF:DIO:IN2?
CONFigure:DIO:OUT1
Type: Frame-Specific
Description: Set the DO1 type the pin No.9 in System I/O Port.
Setting Syntax: CONFigure:DIO:OUT1<space><NR1>
Setting Parameters: <NR1>, 0 ~ 7
0:NONE
1:OCP TEST PASS-H
2:OCP TEST FAIL-L
3:GONG TOTAL PASS-H
4:GONG TOTAL FAIL-L
5:OTP OVP OCP OPP REV-H
6:BUS CTRL. ACT-H
7:BUS CTRL. ACT-L
Setting Example: CONF:DIO:OUT1 2 Set DO1 to OCP TEST FAIL-L.
CONF:DIO:OUT1 0 Set DO1 to NONE.
Query Syntax: CONFigure:DIO:OUT1?
Return Parameters: <NR1>, 0 ~ 7 [Unit = None]