Programmable DC Electronic Load 63600 Series Operation & Programming Manual
FETCh:VOLTage:MAX?
Type: Channel-Specific
Description: Returns the maximum voltage measured at electronic load input in
CZ mode.
Query Syntax: FETCh:VOLTage:MAX?
Return Parameters:<NR2>, [Unit = Voltage]
Query Example: FETC:VOLT:MAX?
Return Example: 8.12
FETCh:VOLTage:MIN?
Type: Channel-Specific
Description: Returns the minimum voltage measured at electronic load input in
CZ mode.
Query Syntax: FETCh:VOLTage:MIN?
Return Parameters:<NR2>, [Unit = Voltage]
Query Example: FETC:VOLT:MIN?
Return Example: 8.12
FETCh:VOLTage:PEAK+?
Type: Channel-Specific
Description: Returns the peak+ voltage measured at electronic load input in CCD,
CCFS and sine wave dynamic mode.
Query Syntax: FETCh:VOLTage:PEAK+?
Return Parameters:<NR2>, [Unit = Voltage]
Query Example: FETC:VOLT:PEAK+?
Return Example: 8.12
FETCh:VOLTage:PEAK+:FREQuency?
Type: Channel-Specific
Description: Returns the frequency at peak+ voltage measured in frequency
sweep mode.
Query Syntax: FETCh:VOLTage:PEAK+:FREQuency?
Return Parameters:<NR2>, [Unit = Hertz]
Query Example: FETC:VOLT:PEAK+:FREQ?
Return Example: 8.12
FETCh:VOLTage:PEAK-?
Type: Channel-Specific
Description: Returns the peak- voltage measured at electronic load input in CCD,
CCFS and sine wave dynamic mode.
Query Syntax: FETCh:VOLTage:PEAK-?
Return Parameters:<NR2>, [Unit = Voltage]
Query Example: FETC:VOLT:PEAK-?
Return Example: 8.12
FETCh:VOLTage:PEAK-:FREQuency?
Type: Channel-Specific
Description: Returns the frequency at peak- voltage measured in frequency
sweep mode.
Query Syntax: FETCh:VOLTage:PEAK-:FREQuency?
Return Parameters:<NR2>, [Unit = Hertz]
Query Example: FETC:VOLT:PEAK-:FREQ?