EasyManuals Logo

Chroma 63600 Series User Manual

Default Icon
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #221 background imageLoading...
Page #221 background image
Remote Operation
5-89
STATus:QUEStionable:EVENt?
Type: Channel-Specific
Description: Record all Questionable conditions that have occurred since last
time the register was read.
Query Syntax: STATus:QUEStionable:EVENt?
Return Parameters:<NR1>
Query Example: STAT:QUES:EVEN? Return the contents of the
Questionable Event register.
Return Example: 24
STATus:QUEStionable:PTRansition
Type: Channel-Specific
Description: Programmable filters determine 0-to-1 transition in the Condition
register will set the corresponding bit of the Event register.
Setting Syntax: STATus:QUEStionable:PTRansition<space><NR1>
Setting Parameters:<NR1>, 0 ~ 65535, Unit = None
Setting Example: STAT:QUES:PTR 4 Set over current bit 2 as 0-to-1.
Query Syntax: STATus:QUEStionable:PTRansition?
Return Parameters:<NR1>
Query Example: STAT:QUES:PTR?
Return Example: 4
STATus:QUEStionable:NTRansition
Type: Channel-Specific
Description: Programmable filters determine 1-to-0 transition in the Condition
register will set the corresponding bit of the Event register.
Setting Syntax: STATus:QUEStionable:NTRansition<space><NR1>
Setting Parameters:<NR1>, 0 ~ 65535, Unit = None
Setting Example: STAT:QUES:NTR 4 Set over current bit 2 as 1-to-0.
Query Syntax: STATus:QUEStionable:PTRansition?
Return Parameters:<NR1>
Query Example: STAT:QUES:NTR?
Return Example: 4

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chroma 63600 Series and is the answer not in the manual?

Chroma 63600 Series Specifications

General IconGeneral
Series63600
Operating Temperature0°C to 40°C
ModesCC, CV
InterfaceGPIB, USB
ProtectionOCP, OTP, OVP
Voltage Resolution1mV
CoolingForced Air

Related product manuals