Remote Operation
5-95
channels in one frame. The frame will ignore the setting if the
channel does not exist.
Setting Syntax: CCSR<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR2>, [Unit=A/μs]
Example: CCSR “1.0,2.5,2.5,10,2.0,5.0,5.0,5.0,0,0”
CPSR
Type: All Channels
Description: Set both of the rising and the falling slew rate of CP mode to the ten
channels in one frame. The frame will ignore the setting if the
channel does not exist.
Setting Syntax: CPSR<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR2>, [Unit=A/μs]
Example: CRSR “1.0,2.5,2.5,10,2.0,5.0,5.0,5.0,0,0
CDL1
Type: All Channels
Description: Set the current level 1(L1) of CCDL/CCDM/CCDH mode to the ten
channels in one frame. The frame will ignore the setting if the
channel does not exist.
Setting Syntax: CDL1<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR2>, [Unit=Ampere]
Example: CDL1 “1.0,1,2.5,5.0,10.5,4.5,2.0,2.0,0,0
CDL2
Type: All Channels
Description: Set the current level 2(L2) of CCDL/CCDM/CCDH mode to the ten
channels in one frame. The frame will ignore the setting if the
channel does not exist.
Setting Syntax: CDL2<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR2>, [Unit=Ampere]
Example: CDL2 “1.0,1,2.5,5.0,10.5,4.5,2.0,2.0,0,0
CDT1
Type: All Channels
Description: Set the active time T1 of current level 1(L1) of CCDL/CCDM/CCDH
mode to the ten channels in one frame. The frame will ignore the
setting if the channel does not exist.
Setting Syntax: CDT1<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR2>, [Unit=Second]
Example: CDT1 “1.0,1,2.5,5.0,10.5,4.5,2.0,2.0,0,0”
CDT2
Type: All Channels
Description: Set the active time T2 of current level 2(L2) of CCDL/CCDM/CCDH
mode to the ten channels in one frame. The frame will ignore the
setting if the channel does not exist.
Setting Syntax: CDT2<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR2>, [Unit=Second]
Example: CDT2 “1.0,1,2.5,5.0,10.5,4.5,2.0,2.0,0,0”