Programmable DC Electronic Load 63600 Series Operation & Programming Manual
Description: Set the falling slew rate of CP mode to the ten channels in one
frame. The frame will ignore the setting when the channel does not
exist.
Setting Syntax: CPF<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR2>, [Unit=A/μs]
Example: CPF “1.0,2.5,2.5,10,2.0,5.0,5.0,5.0,0,0”
LAT
Type: All Channels
Description: Set the action type of Von to the ten channels in one frame. The
frame will ignore the setting when the channel does not exist.
Setting Syntax: LAT<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR1>, 0: OFF, 1: ON
Example: LAT “0,1,1,1,0,1,0,1,0,0”
GO
Type: All Channels
Description: This command starts/stops current sinking of the ten channels in
one frame. The frame will ignore the setting if the channel does not
exist.
Setting Syntax: GO<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR1>, 0: OFF, 1: ON, Other Value: no action
Example: GO “0,1,1,1,0,1,0,1,0,0”
VRB
Type: All Channels
Description: This command sets the voltage range of CC mode to the ten
channels in one frame. The frame will ignore the setting if the
channel does not exist.
Setting Syntax: VRB<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR1>, 0: LOW range, 1: MIDDLE range, 2: HIGH range, Other
Value: no action
Example: VRB “0,1,1,1,0,1,0,2,0,0”
VR
Type: All Channels
Description: This command sets the voltage range of CC mode to the ten
channels in one frame. The frame will ignore the setting when the
channel does not exist. The unit of the setting value is volt. Please
refer to measurement section in the Specification table.
Setting Syntax: VR<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR2>, [Unit=Volt]
Example: VR “1,1,2,16,80,10,80,16,0,0”
VON
Type: All Channels
Description: This command sets Von voltage to the ten channels in one frame.
The frame will ignore the setting if the channel does not exist.
Setting Syntax: VON<space>“n,n,n,n,n,n,n,n,n,n”
Setting Parameters: <NR2>, [Unit=Volt]
Example: VON “1.23,1.23,0,0,5,5,12,12,0,0”
CCSR
Type: All Channels
Description: Set both of the rising and the falling slew rate of CC mode to the ten