GE+ ACDC Installation and operation manual v11
116 / 121
Each part (A, B and C) has two different buttons explained in the following lines. It is
important that, for example, voltage limits must be sent, the buttons to use are the ones
in the A part.
o Send DC Limits. Once all the limits are introduced in the corresponding part,
press this button and the parameters will be sent to the converter.
o Refresh Limits. This button will show the limits values that are in the converter
in that moment.
If the equipment is in RUN mode with a value that is outside the new
introduced limits, it will change the actual setpoint. For example, if the
converter is in voltage mode with a value of 500V and the user introduces
(and sends) a limit of 300V, the equipment will go to 300V and remain there.
If the limit is only introduced in one channel, it is going to be that channel
the one which go to that limit.
- D: These buttons allow the user to operate with the values of the limits.
o Default Values. The user can define default values that will remember the
equipment as long as it is switched on and lower than the Factory Values.
o All Visible. This button unfreezes all the windows so that the user can set the
Default Values. Remember that the limits are not introduced to the equipment
until Send Limits buttons on each window (A, B and C) are pressed.
o Factory Values. The equipment has its own factory values depending on the
rated power. This button will make these parameters appear in the visible
windows.
o Burn EEPROM. To save the sent values to the equipment and make it remember
them even it is switched off, the EEPROM can be burnt. This step requires a
password.