7. DIGITAL CONTROL
The Cinergia converter can be controlled using Digital Inputs and Outputs.
PIN
INPUT/OUTPUT
NAME
FUNCTION
2 Output OUTPUT LED READY
Turns on when the equipment is
in READY and blinks when the
equipment is doing the
precharge
3 Output OUTPUT LED RUN
Turns on when the equipment is
in RUN
4 Output OUTPUT LED ALARM
Turns on when the equipment is
in ALARM
5 Input INPUT RESET Makes a reset to the equipment
6 Input INPUT RUN/READY
Changes from RUN to READY
and vice versa
8 Input INPUT ENABLE/DISABLE
Changes from ENABLE to
DISABLE and vice versa
9 Input INPUT TRIGGER (GE)
Only available in GE. Allows the
start of a fault
To control the CNG converter through the digital I/O it is necessary to activate the
digital mode via LCD (see on LCD input configuration chapter). While digital control
is activated is activated, remote control and LCD control is not possible. The Control
Mode can only be changed in the Standby and Alarm State through LCD
touchscreen.
Digital outputs can supply up to 8mA maximum.
For more information, please go to chapter ¡Error! No se encuentra el origen de la
referencia. and ¡Error! No se encuentra el origen de la referencia. of this manual.
.