94
Enter Setup
1663 Barcode Scanner User Guide
2.6.4 INTER-FUNCTION DELAY
By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254
in units of milliseconds, to match the computer response time of the keyboard interface.
Such delay time is inserted between every function code (0x01 ~ 0x1F) being
transmitted. The longer the delay time is, the slower the transmission speed will be.
Inter-Function
Delay… (*0~254)
1) Read the barcode above to specify the inter-function delay.
2) Read the “
Decimal Value” barcode on page 219 for the desired inter-function delay (in
milliseconds).
3) Read the “Validate” barcode on the same page to complete this setting.
2.6.5 HID CHARACTER TRANSMIT MODE
By default, HID interface sends data to the host in batch, or use the scanner to read the
“By Character” barcode to process data one character at a time.
*Batch Processing
By Character
2.6.6 SPECIAL KEYBOARD FEATURE
By default, the special keyboard feature is based on the factory definition. You can decide
whether to apply the special keyboard feature. Refer to
Keyboard Wedge Table.
*Apply
Bypass