1.14 USE DIRECT USB CABLE
1663 supports Direct USB interface for charging the battery and/or sending data to the
host in memory mode. Refer to
1.2.2 Memory Mode.
Note: The scanner will not function when it is solely on USB power and without a battery
loaded.
1.14.1 DIRECT USB INTERFACE
When it is set to Memory Mode and connected to computer via the Direct USB cable, the
default output interface becomes “Direct USB Virtual COM”, change it to “Direct USB
HID” if required.
For details on configuring the interface settings, refer to the following sections:
2.6 Direct USB HID
2.7 Direct USB Virtual COM
*Activate Direct
USB Virtual COM
Activate Direct
USB HID
1.14.2 DISABLE DIRECT USB INTERFACE
When connecting the USB cable to the scanner for charging the battery, ensure the
“Disable Direct USB” barcode has been scanned to avoid sending data to the host in
memory mode. In this mode the USB cable function will be charging the battery only.
Disable Direct USB