7-50 P/N 13772-003
Section 7 Cirrus Design
Airplane and Systems Description SR22T
Main Distribution Bus 1 or Main Distribution Bus 2 in the MCU. In the
case of both alternators failing, BAT 1 is connected directly to the
Essential Distribution Bus in the MCU and will power ESS BUS 1 and
ESS BUS 2. In the event of both alternators and BAT 1 failing, BAT 2 is
connected directly to ESS BUS 1.
Main Buses
The circuit breaker panel MAIN BUS 1 and MAIN BUS 2 are powered
by ALT 2 from the MCU Main Distribution Bus 2 and - in the event of
ALT 2 failure - by ALT 1 and BAT 1 from the Main Distribution Bus 2 via
the diode interconnecting the MCU distribution buses through 30-amp
fuses inside the MCU.
The 10-amp AVIONICS circuit breaker on MAIN BUS 1, controlled
through the AVIONICS master switch on the bolster switch panel,
powers all loads on the AVIONICS BUS.
The circuit breaker panel MAIN BUS 3 is powered by ALT 1 and BAT 1
from the MCU Main Distribution Bus 1 through a 30-amp fuse inside
the MCU. In the event of ALT 1 failure, BAT 1 will power MAIN BUS 3.
ALT 2 is prevented from powering MAIN BUS 3 by the isolation diode
interconnecting the MCU distribution buses 1 and 2.
Non-Essential Buses
The circuit breaker panel NON ESS BUS is powered by ALT 2 from the
MCU Main Distribution Bus 2 and - in the event of ALT 2 failure - by
ALT 1 and BAT 1 from the Main Distribution Bus 2 via the diode
interconnecting the MCU distribution buses through 30-amp fuses
inside the MCU. The Avionics Non-Essential Bus is powered through
the 10-amp AVIONICS circuit breaker on MAIN BUS 1 and is
discussed above.
The circuit breaker panel A/C BUS 1 and A/C BUS 2, is powered by
ALT 1 and BAT 1 from the MCU Main Distribution Bus 1 through a 30-
amp fuse inside the MCU. In the event of ALT 1 failure, BAT 1 will
power A/C BUS 1 and A/C BUS 2. ALT 2 is prevented from powering
A/C BUS 1 and A/C BUS 2 by the isolation diode interconnecting the
MCU distribution buses 1 and 2.
Original Issue

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cirrus DESIGN SR22T and is the answer not in the manual?

Cirrus DESIGN SR22T Specifications

General IconGeneral
ManufacturerCirrus Aircraft
ModelSR22T
Seating Capacity5
EngineContinental TSIO-550-K
Horsepower315 hp
AvionicsCirrus Perspective+ by Garmin
TypeSingle-engine piston aircraft
Maximum Speed213 knots
Cruise Speed183 knots
Service Ceiling25, 000 feet
Maximum Takeoff Weight3, 600 lbs
Wingspan38 feet 4 inches
Length26 ft
Height8 feet 11 inches
Safety FeaturesCirrus Airframe Parachute System (CAPS)
Cabin Width49 inches
Cabin Height50 inches

Related product manuals