Cisco CATALYST 2960 - Table 1-2 Providing Network Services (continued); Suggested Design Methods; You can use the switches and switch stacks to create the following:; Cost-effective wiring closet (Figure 1-1)-A cost-effective way to connect many users to the wiring closet is to have a switch stack of up to four Catalyst 2960-S switches. To preserve switch connectivity if one switch in the stack fails, connect the switches as recommended in the hardware installation guide, and enable either cross-stack Etherchannel or cross-stack UplinkFast.

Cisco CATALYST 2960
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-15
Catalyst 2960 Switch Hardware Installation Guide
OL-7075-09
Chapter 3 Switch Installation (8-Port Switches)
Installing the Switch
Rack-Mounting
This section is specific to the Catalyst 2960 8-port switches. For information applicable to the other
Catalyst 2960 switches, see Chapter 2, “Switch Installation (24- and 48-Port Switches).
Installing the Catalyst 2960 8-port switches in a 19-inch rack requires an optional bracket kit that is not
included with the switch. You can order a kit containing the 19-inch rack-mounting brackets and
hardware from Cisco. The kit part number is RCKMNT-19-CMPCT=.
To install the switch in a 19-inch rack, follow the instructions described in these sections:
Attaching Brackets to the Switch, page 3-15
Mounting the Switch in a 19-Inch Rack, page 3-16
Attaching Brackets to the Switch
Figure 3-8 shows how to attach a 19-inch bracket to one side of the switch. Follow the same steps to
attach the second bracket to the opposite side.
Figure 3-8 Attaching the 19-inch Brackets for Rack-Mounting
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you
must take special precautions to ensure that the system remains stable. The
following guidelines are provided to ensure your safety:
This unit should be mounted at the bottom of the rack if it is the only unit in the rack.
When mounting this unit in a partially filled rack, load the rack from the bottom to the
top with the heaviest component at the bottom of the rack.
If the rack is provided with stabilizing devices, install the stabilizers before mounting
or servicing the unit in the rack.
Statement 1006
1 Phillips flat-head screw
2x
3x
4x
5x
6x
7x
8x
1
Catalyst 2960
S
eries
CONSOLE
1x
SPD
DPLX
STAT
SYST
MODE
1
204637