Table 45: Upstream PHY Module Troubleshooting
SolutionPossible CauseProblem
The upstream PHY module should
be re-installed to ensure that it is
properly seated.
The upstream PHY module is not
seated properly.
The PowerGood value 0 in the
output of the show cable card
slot/subslot us-phy display |
include PowerGood command
shows that the upstream PHY
module in the line card is not
powered up.
Refer to the RMA procedure for
more information on service.
The upstream PHY module is
damaged.
Reboot the interface card. If the
STATUS LED does not illuminate,
replace the line card.
The interface card is not booted.The STATUS LED is not
illuminated.
Replace the interface card.The interface card needs to be
replaced.
The REPLACE LED is illuminated
in white color.
Cisco Converged Broadband Routers Hardware Installation Guide
258
Troubleshooting the Cisco cBR
Troubleshooting the Interface Cards in Cisco cBR Chassis

Table of Contents

Other manuals for Cisco cBR Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco cBR Series and is the answer not in the manual?

Cisco cBR Series Specifications

General IconGeneral
CategoryNetwork Router
Modular DesignYes
Operating SystemCisco IOS XE
Model ExamplescBR-8, cBR-4
Product SeriescBR Series
PurposeConverged Broadband Router
DOCSIS SupportDOCSIS 3.1
RedundancyYes
ManagementCisco Prime
Product FamilycBR Series
Downstream Frequency RangeUp to 1.2 GHz
Upstream Frequency RangeUp to 204 MHz
Modulation SchemesQAM
Power SupplyRedundant AC or DC power supplies
Operating Temperature0°C to 40°C
Storage Temperature-40°C to 70°C
Humidity5 to 95% noncondensing

Related product manuals