Catalyst 2950 Desktop Switch Hardware Installation Guide
78-11157-02
Chapter 3      Troubleshooting
Diagnosing Problems
Table 3-1 Common Problems and Solutions
Symptom Possible Cause Resolution
Poor performance or 
excessive errors.
Duplex autonegotiation mismatch. Refer to the Catalyst 2950 
Desktop Switch Software 
Configuration Guide for 
information about identifying 
autonegotiation mismatches.
Cabling distance exceeded.
• Port statistics show excessive 
frame check sequence (FCS), 
late-collision, or alignment 
errors.
• Refer to the Catalyst 2950 
Desktop Switch Software 
Configuration Guide for 
information about 
displaying port statistics.
• For 10BASE-T, 100BASE-TX, 
and 1000BASE-T connections:
–
The distance between the 
port and the attached device 
exceeds 328 feet
(100 meters).
• Reduce cable length to 
within the recommended 
distances. 
–
If the switch is attached to a 
repeater, the total distance 
between the two end 
stations exceeds the cabling 
guidelines.
• Refer to your repeater 
documentation for cabling 
guidelines.
• For GBIC port connections: The 
distance between the GBIC port 
and the attached device exceeds 
the GBIC cabling guidelines.
• Refer to your GBIC 
documentation for cabling 
guidelines.
Bad adapter in attached device.
• Excessive errors found in port 
statistics.
• Run adapter card diagnostic 
utility.
Spanning Tree Protocol (STP) 
checking for possible loops.
Wait 30 seconds for port status 
LED to turn green.