Chapter 2      Installation
Installing the Switch in a Rack
2-10
Catalyst 2950 Desktop Switch Hardware Installation Guide
78-11157-02
Installing the Switch in a Rack
Note Figure 2-1 to Figure 2-14 show the Catalyst 2950-24, 2950G-24-EI-DC, and 
2950G-48-EI switches as examples. You can install other Catalyst 2950 
switches in a rack as shown in these illustrations.
To install the switch in a 19-, 23-, or 24-inch rack, follow these steps:
• Attaching the brackets to the switch
• Mounting the switch in a rack
• Attaching the optional cable guide
Attaching the Brackets to the Switch
The bracket orientation and the screws that you use depend on whether you are 
attaching the brackets to a 19-, 23-, or 24-inch rack. Follow these guidelines:
• When mounting a switch other than a Catalyst 2950G-48-EI switch in a 
19-inch rack, use two of the Phillips flat-head screws to attach the long side 
of the 19- or 24-inch bracket to the switch. See Figure 2-1, Figure 2-2, and 
Figure 2-3.
Warning
To prevent bodily injury when mounting or servicing this unit in a rack, you 
must take special precautions to ensure that the system remains stable. 
The following guidelines are provided to ensure your safety:
• This unit should be mounted at the bottom of the rack if it is the only unit 
in the rack.
• When mounting this unit in a partially filled rack, load the rack from the 
bottom to the top with the heaviest component at the bottom of the rack.
• If the rack is provided with stabilizing devices, install the stabilizers before 
mounting or servicing the unit in the rack.