BeltStaon Setup
Steps to Setup the BeltStaons
• Install the baery.
• “Pair” BeltStaons to the BaseStaon.
• Adjust slot sengs as needed.
• Connect a headset.
• Adjust Mic Gain.
• Adjust Sidetone.
• Congure oponal features:
» Name the BeltStaon.
» Disable unused funcons, channels, and buons.
» Select/disable relay opons as needed.
» Adjust personal preferences.
Baery Selecon and Installaon
The Tempest BeltStaon Baery Compartment holds either one Tempest Lithium-Polymer rechargeable baery or three
standard alkaline AA cells. Lithium-Polymer baeries are the primary power source. High quality alkaline AA cells may be
used in situaons where Lithium-Polymer baeries are not available or are not charged. One Lithium-Polymer baery
comes standard with each Tempest BeltStaon. Addional Lithium-Polymer baeries may be purchased. Contact your
dealer or distributor to purchase addional baeries. The Lithium-Polymer baeries supplied with your Tempest Wireless
system are warranted for 12 months from the date of purchase.
Lithium-Polymer baeries oer up to nine hours of baery life and recharge in
approximately 2¾ hours.
Lithium-Polymer baeries ship from the factory with approximately 50% charge. It
will not damage the Lithium-Polymer baeries to use them without charging them
rst. This will, however result in shorter run me unl the Lithium-Polymer baery
is fully charged. When possible, charge Lithium-Polymer baeries to full capacity to
ensure full baery life prior to use.
Using (3) alkaline AA baeries can provide up to four hours of baery life. Use
only high quality alkaline AA cells. This will provide enough me to fully charge the
Lithium-Polymer baery.
To remove the baery door, press down on the thumb markings and pull the baery door toward the boom of the
BeltStaon.
To remove baeries from the baery compartment, turn the BeltStaon baery side down and tap the boom of the
BeltStaon on the palm of your other hand.
Please be careful to insert alkaline AA baeries according to the marked polarity. All of the alkaline AA cells must be
oriented the same direcon.