Installation of the ADU (60 cm)
98-175666-A Chapter 2: Installation 2-27
2.4.2 To ground the ADU
The ADU must be grounded using one of the mounting bolts. To ground the ADU do as
follows:
1. Clean the metal underneath the head of at least one bolt of insulating protective
coating and use a serrated washer to obtain a good ground connection. For optimum
grounding connect the ground wire to the bolt marked in the figure below.
2. Tighten the bolt. Use stainless steel bolts and washers.
Tightening torque value: 30 Nm.
3. Seal the area suitably to avoid corrosion of the grounding point (recommended).
If the ADU cannot or should not be electrically connected directly to the mounting surface,
use a separate grounding cable to make the connection between the ADU and the common
ground to which the BDU is also connected.
Figure 2-31: ADU, thread for optimum grounding (60 cm)
282.8
R221
R238
18
73.5
200
200
220
226.4
THREAD for GROUNDING
m)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the COBHAM SAILOR Global Xpress Modem Unit GMU and is the answer not in the manual?

COBHAM SAILOR Global Xpress Modem Unit GMU Specifications

General IconGeneral
BrandCOBHAM
ModelSAILOR Global Xpress Modem Unit GMU
CategoryAntenna
LanguageEnglish

Related product manuals